Photo of Motorola AN 200
Motorola logo

Motorola AN 200 RFID Antenna

The Motorola AN 200 provides the convenience of a versatile antenna that can be utilized throughout your enterprise, from the warehouse floor and production line to outside the dock door. Able to withstand extreme heat and cold as well as moisture and vibration, the AN 200 is ideal for nearly any application, including retail, manufacturing, wholesale distribution, healthcare, government and more. This all-purpose antenna can be used in standard RFID applications with power levels up to one watt, as well as custom high-power applications requiring up to 20 watts. The antenna is traditionally used in pairs, with right and left hand polarization.


AN 200 Options
Part # DescriptionAvailabilityPriceOrder
ANT-71721-01 AN 200, Antenna (Outdoor, Left) For The Ar400 and Xr400 Ships Free Today $261.98
AN2030 WHIP ANTENNA STUBBY DUAL BAND 802.11a/b/gN 2.4/5GHz RPSMA CONN Ships Free Today $17.94
Retail $20.50
Save 12%
ANT-71720-01 AN 200, Antenna (Outdoor, Right) For The Ar400 and Xr400 Check Availability Call for Details
ANT-69793-01 AN 200, Antenna, Small Area Antenna, With Mounting Bracket Check Availability Call for Details
ANT-69792-01 AN 200, Antenna, Small Area Antenna, Without Mounting Bracket Check Availability Call for Details

Motorola AN 200 Details

The AN200 will perform reasonably well in EU frequency in most applications.
See footnotes for additional information 1

Performance Characteristics

Nominal impedance
50 Ohm

20 watts (max. input)

Front to back ratio
<10 db

Frequency range2 
902-928 MHz

6.0 dBi linear

Axial ratio
<3 dB

Voltage Standing Wave Ratio (VSWR)
20 dB (1.22)

Physical Characteristics

Type "N" Female


Single port

Dimensions (with mounting screws)
11.1 x 11.1 x 1.9 in. (28.19 28.19 x 4.83 cm) H x W x D

3 lbs (1.26 kg)

Connector position

User Environment

Temperature shock test
IEC-68-2-14 (-40° rising to 158° F/-40° rising to 70° C)

Humidity test
IEC-68-2-30 (77° to 104° F/-25° to 40°

Random vibration test
IEC-68-2-6 (10 to 150 Hz, 05 g, 1 hour in each of 2 axes)

Environmental sealing

Heat test
IEC-68-2-2 (158° F/70° C for 24 hours)

Salt fog test
IEC-68-2-11 (96 hours, repetitive cycling)

Outdoor use

Operating temperature
-40° to +149° F (-40° to +65° C)

Cold test
IEC-68-2-1 (-40° F/-40° C for 24 hours)

Rain test
IEC-68-2-18 (8 hours minimum in rain chamber at 43 psi)

Temperature shock test
IEC-68-2-14 (-40° F rising to 158° F (-40° C rising to 70° C) in 10 cycles of 60 minutes each)

Humidity test
IEC-68-2-30 (77° to 104° F (-25° to 40° C)), 24 hour cycles of 90% relative humidity

DC: 10 kOhm +/- 5%